Li run August 2006
Target
issues:
* Experiment IS446
* #335 Ta, W surface ionization
* Mass-markers Be and Li
*
* Yield check
“From Ta308 target benchmark, yield on 8Li is 3.10^7/muC. Yesterday
morning, it was 4.10^6 for this target. Taking for granted separator has been
optimized yesterday by a x2 factor, we are now at a x4
factor below Ta308.” (ISO-
isotopes run: 8Li3+
timing: 18 ms
breeding time for 3+, 20 ms cooling time
currents: With 3E13 p/p, 6 p/sc
trap inj plate – negative value
with beam on it
BTS.FC20 =
10 pA in the peak
RFQ.FC20 =
8pA of O6+, only 0.6 pA of 8Li3+
efficiency and energy:
*
* TRAP: 20% for 7Li (~100 pA inj, 20 ms cooling and short
gate) <5% Ne in the trap
* EBIS eff
13% for 7Li3+ with 18 ms breeding time
* Linac
transmission and energy: 75%-85% for A/q=2.666 and 3.15 MeV/u
(50Hz/900us)
For 39K form
Trap inj
plate=18 pA, BTS.FC20=11.5 pA
(some Ne), RFQFC20=18 pa (10+)
Trap eff < 64%; EBIS eff
> 15.6%; Total eff = 10%
comments:
* A 25ug/cm^2 C foil was used at the
linac output to remove 16O
* An extra 4ug/cm^2 foil was
installed between the RFQ and buncher. This seems to
give good results (factor of 8 improvement in Li/O
ratio) but could not be used for data taking due to the low beam intensity.
* Slow extraction was tried. Long
beam pulse on SEP.FC80 and at experiment, but not that
much more events.
technical problems:
lessons learned: